This spec focuses on a new, additional SNAT implementation to DragonFlow (which we will henceforth refer to as “Distributed SNAT”) that trades off some functionality in favor of scale, performance and ease of use (all highlighted in “Problem Description” section).
All references to IP in this spec refer to IPv4 addressing scheme (IPv6 is out of scope for this spec).
The main functionality difference between the legacy DragonFlow implementation of SNAT and “Distributed SNAT”, is that with legacy DragonFlow SNAT the cloud admin reserves a single external IP address (from a limited pre-allocated pool), which is used to masquerade multiple virtual hosts that egress via the same router port, sharing the same external IP.
With the “Distributed SNAT” solution, in contrast, the cloud admin reserves an external IP address (from a limited pre-allocated pool) for every [compute node, tenant gateway] pair/compute node (see Flow section for implementation alternatives). This way north/south traffic of every VM will be routed out locally via external IP of hosting compute node.
The main advantage of “Distributed SNAT” is the distribution of the NAT/PAT function among the compute nodes, bypassing the network node.
The requirement of having dedicated network node will be more flimsy with “Distributed SNAT” probably apart from VPNaaS deployment.
Currently, when the cloud admin wants to allow multiple VMs to access external networks (e.g. internet), he/she can either assign a floating IP to each VM (DNAT), or assign just one floating IP to the router that she uses as a default gateway for all the VMs (SNAT).
The downside of DNAT is that the number of external IP addresses is very limited, and therefore it requires that the cloud admin either “switch” floating IPs between VMs (complicated), or obtain enough external IPs (expensive).
The downside of SNAT is that all outbound traffic from the VMs that use it as default gateway will go through the network node that hosts the router, effectively creating a network bottleneck and single point of failure for multiple VMs if L3 HA is not deployed.
This spec outlines an additional SNAT model that places the NAT/PAT on each compute node. In order for this design to work in a real world deployment, compute nodes should be attached to external network via the underlying networking infrastructure.
Such SNAT model is changing the concept of legacy router where single gateway port is present. Both Neutron DVR and current DragonFlow implementations follow legacy concept in terms of single gateway port and same internal router port (in terms of MAC/IP addressing) copied across compute nodes. However this model redefines single gateway port concept actively defining more than one gateway port on single distributed router.
When the compute node can route outbound traffic, VMs hosted on it do not need to be routed through the network node. Instead, they will be routed locally from the compute node.
Our goal is to preserve Neutron reference implementation and concentrate on DragonFlow plugin update. Therefore “Distributed SNAT” should not be reflected in Neutron database. DragonFlow plugin should manage additional data on compute node locally. New model not requires extra Neutron ports on compute nodes, but it does require every compute node to have IP address on external network.
This model will take advantage of common DragonFlow deployed component L2 OVS switch and OpenFlow protocol to achieve “Distributed SNAT” feature implementation for multi-tenant cloud as local compute node connectivity enhancement.
In order to achieve DragonFlow pipeline flow change for north/south traffic new DragonFlow application is required. The easy way to enable/disable “Distributed SNAT” feature is a presence of SNATApp application in the application list of DragonFlow configuration file.
DragonFlow controller may monitor external connectvity and perform a fallback to Neutron SNAT when connectivity outage is detected.
New DragonFlow application should handle north/south traffic on each compute node. East/west traffic between VMs of different tenants deployed on different compute nodes falls into this category as well. Application should handle local ports (VMs) add/remove events and install/uninstall appropriate NAT flows as described in Ingress/Egress sections below.
DragonFlow controller should have proper installed rules priorities to prioritize DNAT over “Distributed SNAT”
There are number of solutions to achieve “Distributed SNAT”. Every solution has its advantages and weak points.
[1] Single external IP per compute node solution requires double NAT.
[2] External IP address per [compute node, tenant gateway] pair
Note: excessive external IPs consumption in solution [2] can be further reduced by provider router translation that should lead to single IP per tenant. Such scheme is out of scope of this spec.
Neutron SNAT implementation consumes number of external IPs equivalent to number of tenants + single address reserved for gateway on network node.
We want to achieve a reasonably small external IP addresses use and at the same effort solve a connectivity bottleneck problem. Unfortunately it seems that none of solution alternatives achieves both targets. However implementing more than one alternative may give a cloud admin set of tools to reach desired result in terms of “Distributed SNAT”.
In alternative [1], all private networks on br-int IP should be reached via single static external IP. This scheme requires ARP responder flows for external IP address similar to floating IP management in DNAT application.
This section describes all the handling in the pipeline for north/south traffic and provides design details for solution alternative [1].
NAT translation can take place natively in OVS that supports NAT feature starting from version 2.6.x.
OVS native NAT support allows to untie need for linux namespaces required by Neutron SNAT implementation.
“Distributed SNAT” results a single external IP per compute node. We want to achieve this with a single address translation. However general deployment scenario allows for address collision, e.g. where different tenant have same subnet range for a private subnet, which leave us a tangible possibility of exactly same 4-tuple (IP1, port1, IP2, port2) produced by different tenant VMs. 4-tuple collision makes it impossible to pass single zone connection tracking correctly.
To avoid this address overlap issue, we will encode the source’s identifier as the source IP (Similar to the solution used in the metadata service).
Specifically, we will store the original source IP in the connection tracking’s metadata, e.g. ct_mark field. We will store the source’s identifier (available in reg6) in the source IP, and then we will pass it through NAT.
On the return packet, the un-NATted packet will have the virtual host’s identifier in the destination address. We will move that to reg7, and set the destination address to the value in ct_mark (which we stored on egress).
OVS’s connection tracking requires a zone to be specified, to differentiate SNAT traffic from east-west traffic. A constant value will be used for the zone, either selected statically, or dynamically to avoid collision.
Below diagram outlines single compute node and address manipulation: Source IP address - 32-bit unsigned integer translated to host unique 32-bit unsigned integer.
+ Tenant 1 + Tenant 1 + Tenant 2
| 10.0.0.1 | 10.0.0.2 | 10.0.0.1
| | |
+----|-----------------|-------------------|---------------+
| \--------\ /------/ | br-int |
| v v |
| 10.0.0.1->101| 10.0.0.2-> 102 | 10.0.0.2->103 |
| | | |
| v v |
| \-------------\ /-----------/ |
+-----------------------------v----------------------------+
| NAT
public net | 172.24.4.2
+-----------------------------|----------------------------+
| | br-ex |
+-----------------------------|----------------------------+
v
No change
Below is sample implementation of (*) marked step in OVS flows.
table=20, priority=100,ip,actions=move:OXM_NX_IP_SRC->NXM_NX_REG8[],
move:NXM_REG6[]->OXM_NX_IP_SRC[],
actions=resubmit(,30)
table=30, priority=50,ip actions=ct(commit,table=31,
zone=65000,nat(src=172.24.4.2),
exec(move:NXM_NX_REG8[0..31]->NXM_NX_CT_MARK[])
table=31, priority=50,ip
actions=mod_dl_src:91:92:93:94:95:96,mod_dl_dst:42:b9:63:88:a0:48,
resubmit(,66)
Below is sample implementation of (*) marked step in OVS flows.
table=0, priority=5, ip, actions=resubmit(,15)
-- NAT conn. track phase -----------
table=15, priority=50,ip actions=ct(table=16,nat,zone=65000)
-- NAT actions phase ---------------
table=16, priority=50,ip
actions=mod_dl_src:91:92:93:94:95:96,mod_dl_dst:fa:16:3e:95:bf:e9,
move:OXM_NX_IP_DST[]->NXM_NX_REG7[],
move:NXM_NX_CT_MARK[]->OXM_NX_IP_DST[0..31],resubmit(,78)