iDRAC driver

Overview

The integrated Dell Remote Access Controller (iDRAC) is an out-of-band management platform on Dell EMC servers, and is supported directly by the idrac hardware type. This driver uses the Dell Web Services for Management (WSMAN) protocol and the standard Distributed Management Task Force (DMTF) Redfish protocol to perform all of its functions.

iDRAC hardware is also supported by the generic ipmi and redfish hardware types, though with smaller feature sets.

Key features of the Dell iDRAC driver include:

  • Out-of-band node inspection

  • Boot device management and firmware management

  • Power management

  • RAID controller management and RAID volume configuration

  • BIOS settings configuration

Ironic Features

The idrac hardware type supports the following Ironic interfaces:

Prerequisites

The idrac hardware type requires the python-dracclient library to be installed on the ironic conductor node(s) if an Ironic node is configured to use an idrac-wsman interface implementation, for example:

sudo pip install 'python-dracclient>=3.1.0'

Additionally, the idrac hardware type requires the sushy library to be installed on the ironic conductor node(s) if an Ironic node is configured to use an idrac-redfish interface implementation, for example:

sudo pip install 'python-dracclient>=3.1.0' 'sushy>=2.0.0'

Enabling

The iDRAC driver supports WSMAN for the bios, inspect, management, power, raid, and vendor interfaces. In addition, it supports Redfish for the bios, inspect, management, power, and raid interfaces. The iDRAC driver allows you to mix and match WSMAN and Redfish interfaces.

The idrac-wsman implementation must be enabled to use WSMAN for an interface. The idrac-redfish implementation must be enabled to use Redfish for an interface.

To enable the idrac hardware type with the minimum interfaces, all using WSMAN, add the following to your /etc/ironic/ironic.conf:

[DEFAULT]
enabled_hardware_types=idrac
enabled_management_interfaces=idrac-wsman
enabled_power_interfaces=idrac-wsman

To enable all optional features (BIOS, inspection, RAID, and vendor passthru) using Redfish where it is supported and WSMAN where not, use the following configuration:

[DEFAULT]
enabled_hardware_types=idrac
enabled_bios_interfaces=idrac-redfish
enabled_inspect_interfaces=idrac-redfish
enabled_management_interfaces=idrac-redfish
enabled_power_interfaces=idrac-redfish
enabled_raid_interfaces=idrac-redfish
enabled_vendor_interfaces=idrac-redfish

Below is the list of supported interface implementations in priority order:

Interface

Supported Implementations

bios

idrac-wsman, idrac-redfish, no-bios

boot

ipxe, pxe, idrac-redfish-virtual-media

console

no-console

deploy

direct, ansible, ramdisk

inspect

idrac-wsman, idrac, idrac-redfish, inspector, no-inspect

management

idrac-wsman, idrac, idrac-redfish

network

flat, neutron, noop

power

idrac-wsman, idrac, idrac-redfish

raid

idrac-wsman, idrac, idrac-redfish, no-raid

rescue

no-rescue, agent

storage

noop, cinder, external

vendor

idrac-wsman, idrac, idrac-redfish, no-vendor

Note

idrac is the legacy name of the WSMAN interface. It has been deprecated in favor of idrac-wsman and may be removed in a future release.

Protocol-specific Properties

The WSMAN and Redfish protocols require different properties to be specified in the Ironic node’s driver_info field to communicate with the bare metal system’s iDRAC.

The WSMAN protocol requires the following properties:

  • drac_username: The WSMAN user name to use when communicating with the iDRAC. Usually root.

  • drac_password: The password for the WSMAN user to use when communicating with the iDRAC.

  • drac_address: The IP address of the iDRAC.

The Redfish protocol requires the following properties:

  • redfish_username: The Redfish user name to use when communicating with the iDRAC. Usually root.

  • redfish_password: The password for the Redfish user to use when communicating with the iDRAC.

  • redfish_address: The URL address of the iDRAC. It must include the authority portion of the URL, and can optionally include the scheme. If the scheme is missing, https is assumed.

  • redfish_system_id: The Redfish ID of the server to be managed. This should always be: /redfish/v1/Systems/System.Embedded.1.

For other Redfish protocol parameters see Redfish driver.

If using only interfaces which use WSMAN (idrac-wsman), then only the WSMAN properties must be supplied. If using only interfaces which use Redfish (idrac-redfish), then only the Redfish properties must be supplied. If using a mix of interfaces, where some use WSMAN and others use Redfish, both the WSMAN and Redfish properties must be supplied.

Enrolling

The following command enrolls a bare metal node with the idrac hardware type using WSMAN for all interfaces:

baremetal node create --driver idrac \
    --driver-info drac_username=user \
    --driver-info drac_password=pa$$w0rd \
    --driver-info drac_address=drac.host

The following command enrolls a bare metal node with the idrac hardware type using Redfish for all interfaces:

baremetal node create --driver idrac \
    --driver-info redfish_username=user \
    --driver-info redfish_password=pa$$w0rd \
    --driver-info redfish_address=drac.host \
    --driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
    --bios-interface idrac-redfish \
    --inspect-interface idrac-redfish \
    --management-interface idrac-redfish \
    --power-interface idrac-redfish \
    --raid-interface idrac-redfish \
    --vendor-interface idrac-redfish

The following command enrolls a bare metal node with the idrac hardware type assuming a mix of Redfish and WSMAN interfaces are used:

baremetal node create --driver idrac \
    --driver-info drac_username=user \
    --driver-info drac_password=pa$$w0rd
    --driver-info drac_address=drac.host \
    --driver-info redfish_username=user \
    --driver-info redfish_password=pa$$w0rd \
    --driver-info redfish_address=drac.host \
    --driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
    --bios-interface idrac-redfish \
    --inspect-interface idrac-redfish \
    --management-interface idrac-redfish \
    --power-interface idrac-redfish

Note

If using WSMAN for the management interface, then WSMAN must be used for the power interface. The same applies to Redfish. It is currently not possible to use Redfish for one and WSMAN for the other.

BIOS Interface

The BIOS interface implementations supported by the idrac hardware type allows BIOS to be configured with the standard clean/deploy step approach.

Example

A clean step to enable Virtualization and SRIOV in BIOS of an iDRAC BMC would be as follows:

{
  "target":"clean",
  "clean_steps": [
    {
      "interface": "bios",
      "step": "apply_configuration",
      "args": {
        "settings": [
          {
            "name": "ProcVirtualization",
            "value": "Enabled"
          },
          {
            "name": "SriovGlobalEnable",
            "value": "Enabled"
          }
        ]
      }
    }
  ]
}

See the Known Issues for a known issue with factory_reset clean step. For additional details of BIOS configuration, see BIOS Configuration.

Inspect Interface

The Dell iDRAC out-of-band inspection process catalogs all the same attributes of the server as the IPMI driver. Unlike IPMI, it does this without requiring the system to be rebooted, or even to be powered on. Inspection is performed using the Dell WSMAN or Redfish protocol directly without affecting the operation of the system being inspected.

The inspection discovers the following properties:

  • cpu_arch: cpu architecture

  • cpus: number of cpus

  • local_gb: disk size in gigabytes

  • memory_mb: memory size in megabytes

Extra capabilities:

  • boot_mode: UEFI or BIOS boot mode.

  • pci_gpu_devices: number of GPU devices connected to the bare metal.

It also creates baremetal ports for each NIC port detected in the system. The idrac-wsman inspect interface discovers which NIC ports are configured to PXE boot and sets pxe_enabled to True on those ports. The idrac-redfish inspect interface does not currently set pxe_enabled on the ports. The user should ensure that pxe_enabled is set correctly on the ports following inspection with the idrac-redfish inspect interface.

Management Interface

The management interface for idrac-redfish supports:

  • updating firmware on nodes using a manual cleaning step. See Redfish driver for more information on firmware update support.

  • updating system and getting its inventory using configuration molds. For more information see Import and export configuration.

Import and export configuration

The clean and deploy steps provided in this section allow to configure the system and collect the system inventory using configuration mold files.

The introduction of this feature in the Wallaby release is experimental.

These steps are:

  • export_configuration with the export_configuration_location input parameter to export the configuration from the existing system.

  • import_configuration with the import_configuration_location input parameter to import the existing configuration mold into the system.

  • import_export_configuration with the export_configuration_location and import_configuration_location input parameters. This step combines the previous two steps into one step that first imports existing configuration mold into system, then exports the resulting configuration.

The input parameters provided include the URL where the configuration mold is to be stored after the export, or the reference location for an import. For more information on setting up storage and available options see Storage setup.

Configuration molds are JSON files that contain three top-level sections: bios, raid and oem. The following is an example of a configuration mold:

{
  "bios": {
    "reset": false,
    "settings": [
      {
        "name": "ProcVirtualization",
        "value": "Enabled"
      },
      {
        "name": "MemTest",
        "value": "Disabled"
      }
    ]
  }
  "raid": {
    "create_nonroot_volumes": true,
    "create_root_volume": true,
    "delete_existing": false,
    "target_raid_config": {
      "logical_disks": [
        {
          "size_gb": 50,
          "raid_level": "1+0",
          "controller": "RAID.Integrated.1-1",
          "volume_name": "root_volume",
          "is_root_volume": true,
          "physical_disks": [
            "Disk.Bay.0:Encl.Int.0-1:RAID.Integrated.1-1",
            "Disk.Bay.1:Encl.Int.0-1:RAID.Integrated.1-1"
          ]
        },
        {
          "size_gb": 100,
          "raid_level": "5",
          "controller": "RAID.Integrated.1-1",
          "volume_name": "data_volume",
          "physical_disks": [
            "Disk.Bay.2:Encl.Int.0-1:RAID.Integrated.1-1",
            "Disk.Bay.3:Encl.Int.0-1:RAID.Integrated.1-1",
            "Disk.Bay.4:Encl.Int.0-1:RAID.Integrated.1-1"
          ]
        }
      ]
    }
  }
  "oem": {
    "interface": "idrac-redfish",
    "data": {
      "SystemConfiguration": {
        "Model": "PowerEdge R640",
        "ServiceTag": "8CY9Z99",
        "TimeStamp": "Fri Jun 26 08:43:15 2020",
        "Components": [
          {
            [...]
            "FQDD": "NIC.Slot.1-1-1",
            "Attributes": [
              {
              "Name": "BlnkLeds",
              "Value": "15",
              "Set On Import": "True",
              "Comment": "Read and Write"
              },
              {
              "Name": "VirtMacAddr",
              "Value": "00:00:00:00:00:00",
              "Set On Import": "False",
              "Comment": "Read and Write"
              },
              {
              "Name": "VirtualizationMode",
              "Value": "NONE",
              "Set On Import": "True",
              "Comment": "Read and Write"
              },
            [...]
            ]
          }
        ]
      }
  }
}

Currently, the OEM section is the only section that is supported. The OEM section uses the iDRAC Server Configuration Profile (SCP) and can be edited as necessary if it complies with the SCP. For more information about SCP and its capabilities, see SCP_Reference_Guide.

To replicate the system configuration to that of a similar system, perform the following steps:

  1. Configure a golden, or one to many, system.

  2. Use the export_configuration step to export the configuration to the wanted location.

  3. Adjust the exported configuration mold for other systems to replicate. For example, remove sections that do not need to be replicated such as iDRAC connection settings. The configuration mold can be accessed directly from the storage location.

  4. Import the selected configuration mold into the other systems using the import_configuration step.

It is not mandatory to use export_configuration step to create a configuration mold. Upload the file to a designated storage location without using Ironic if it has been created manually or by other means.

Storage setup

To start using these steps, configure the storage location. The settings can be found in the [molds] section. Configure the storage type from the [molds]storage setting. Currently, swift, which is enabled by default, and http are supported.

In the setup input parameters, the complete HTTP URL is used. This requires that the containers (for swift) and the directories (for http) are created beforehand, and that read/write access is configured accordingly.

Note

Use of TLS is strongly advised.

This setup configuration allows a user to access these locations outside of Ironic to list, create, update, and delete the configuration molds.

For more information see Swift configuration and HTTP configuration.

Swift configuration

To use Swift with configuration molds,

  1. Create the containers to be used for configuration mold storage.

  2. For Ironic Swift user that is configured in the [swift] section add read/write access to these containers.

HTTP configuration

To use HTTP server with configuration molds,

  1. Enable HTTP PUT support.

  2. Create the directory to be used for the configuration mold storage.

  3. Configure read/write access for HTTP Basic access authentication and provide user credentials in [molds]user and [molds]password fields.

The HTTP web server does not support multitenancy and is intended to be used in a stand-alone Ironic, or single-tenant OpenStack environment.

RAID Interface

See RAID Configuration for more information on Ironic RAID support.

RAID interface of redfish hardware type can be used on iDRAC systems. Compared to redfish RAID interface, using idrac-redfish adds:

  • Waiting for real-time operations to be available on RAID controllers. When using redfish this is not guaranteed and reboots might be intermittently required to complete,

  • Converting non-RAID disks to RAID mode if there are any,

  • Clearing foreign configuration, if any, after deleting virtual disks.

The following properties are supported by the iDRAC WSMAN and Redfish RAID interface implementation:

Note

When using idrac-redfish for RAID interface iDRAC firmware greater than 4.40.00.00 is required.

Mandatory properties

  • size_gb: Size in gigabytes (integer) for the logical disk. Use MAX as size_gb if this logical disk is supposed to use the rest of the space available.

  • raid_level: RAID level for the logical disk. Valid values are 0, 1, 5, 6, 1+0, 5+0 and 6+0.

Note

JBOD and 2 are not supported, and will fail with reason: ‘Cannot calculate spans for RAID level.’

Optional properties

  • is_root_volume: Optional. Specifies whether this disk is a root volume. By default, this is False.

  • volume_name: Optional. Name of the volume to be created. If this is not specified, it will be auto-generated.

Backing physical disk hints

See RAID Configuration for more information on backing disk hints.

These are machine-independent information. The hints are specified for each logical disk to help Ironic find the desired disks for RAID configuration.

  • disk_type

  • interface_type

  • share_physical_disks

  • number_of_physical_disks

Backing physical disks

These are Dell RAID controller-specific values and must match the names provided by the iDRAC.

  • controller: Mandatory. The name of the controller to use.

  • physical_disks: Optional. The names of the physical disks to use.

Note

physical_disks is a mandatory parameter if the property size_gb is set to MAX.

Examples

Creation of RAID 1+0 logical disk with six disks on one controller:

{ "logical_disks":
  [ { "controller": "RAID.Integrated.1-1",
      "is_root_volume": "True",
      "physical_disks": [
        "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
        "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1",
        "Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1",
        "Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1",
        "Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1",
        "Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
      "raid_level": "1+0",
      "size_gb": "MAX"}]}

Manual RAID Invocation

The following command can be used to delete any existing RAID configuration. It deletes all virtual disks/RAID volumes, unassigns all global and dedicated hot spare physical disks, and clears foreign configuration:

baremetal node clean --clean-steps \
  '[{"interface": "raid", "step": "delete_configuration"}]' ${node_uuid}

The following command shows an example of how to set the target RAID configuration:

baremetal node set --target-raid-config '{ "logical_disks":
  [ { "controller": "RAID.Integrated.1-1",
      "is_root_volume": true,
      "physical_disks": [
        "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
        "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
      "raid_level": "0",
      "size_gb": "MAX"}]}' ${node_uuid}

The following command can be used to create a RAID configuration:

baremetal node clean --clean-steps \
  '[{"interface": "raid", "step": "create_configuration"}]' <node>

When the physical disk names or controller names are not known, the following Python code example shows how the python-dracclient can be used to fetch the information directly from the Dell bare metal:

import dracclient.client


client = dracclient.client.DRACClient(
    host="192.168.1.1",
    username="root",
    password="calvin")
controllers = client.list_raid_controllers()
print(controllers)

physical_disks = client.list_physical_disks()
print(physical_disks)

Or using sushy with Redfish:

import sushy


client = sushy.Sushy('https://192.168.1.1', username='root', password='calvin', verify=False)
for s in client.get_system_collection().get_members():
  print("System: %(id)s" % {'id': s.identity})
  for c in system1.storage.get_members():
      print("\tController: %(id)s" % {'id': c.identity})
      for d in c.drives:
        print("\t\tDrive: %(id)s" % {'id': d.identity})

Vendor Interface

idrac-wsman

Dell iDRAC BIOS management is available through the Ironic WSMAN vendor passthru interface.

Method Name

HTTP Method

Description

abandon_bios_config

DELETE

Abandon a BIOS configuration job.

commit_bios_config

POST

Commit a BIOS configuration job submitted through set_bios_config. Required argument: reboot - indicates whether a reboot job should be automatically created with the config job. Returns a dictionary containing the job_id key with the ID of the newly created config job, and the reboot_required key indicating whether the node needs to be rebooted to execute the config job.

get_bios_config

GET

Returns a dictionary containing the node’s BIOS settings.

list_unfinished_jobs

GET

Returns a dictionary containing the key unfinished_jobs; its value is a list of dictionaries. Each dictionary represents an unfinished config job object.

set_bios_config

POST

Change the BIOS configuration on a node. Required argument: a dictionary of {AttributeName: NewValue}. Returns a dictionary containing the is_commit_required key indicating whether commit_bios_config needs to be called to apply the changes and the is_reboot_required value indicating whether the server must also be rebooted. Possible values are true and false.

Examples

Get BIOS Config
baremetal node passthru call --http-method GET <node> get_bios_config

Snippet of output showing virtualization enabled:

{"ProcVirtualization": {
      "current_value": "Enabled",
      "instance_id": "BIOS.Setup.1-1:ProcVirtualization",
      "name": "ProcVirtualization",
      "pending_value": null,
      "possible_values": [
          "Enabled",
          "Disabled"],
      "read_only": false }}

There are a number of items to note from the above snippet:

  • name: this is the name to use in a call to set_bios_config.

  • current_value: the current state of the setting.

  • pending_value: if the value has been set, but not yet committed, the new value is shown here. The change can either be committed or abandoned.

  • possible_values: shows a list of valid values which can be used in a call to set_bios_config.

  • read_only: indicates if the value is capable of being changed.

Set BIOS Config
baremetal node passthru call <node> set_bios_config --arg "name=value"

Walkthrough of perfoming a BIOS configuration change:

The following section demonstrates how to change BIOS configuration settings, detect that a commit and reboot are required, and act on them accordingly. The two properties that are being changed are:

  • Enable virtualization technology of the processor

  • Globally enable SR-IOV

baremetal node passthru call <node> set_bios_config \
  --arg "ProcVirtualization=Enabled" \
  --arg "SriovGlobalEnable=Enabled"

This returns a dictionary indicating what actions are required next:

{
  "is_reboot_required": true,
  "is_commit_required": true
}
Commit BIOS Changes

The next step is to commit the pending change to the BIOS. Note that in this example, the reboot argument is set to true. The response indicates that a reboot is no longer required as it has been scheduled automatically by the commit_bios_config call. If the reboot argument is not supplied, the job is still created, however it remains in the scheduled state until a reboot is performed. The reboot can be initiated through the Ironic power API.

baremetal node passthru call <node> commit_bios_config \
  --arg "reboot=true"
{
  "job_id": "JID_499377293428",
  "reboot_required": false
}

The state of any executing job can be queried:

baremetal node passthru call --http-method GET <node> list_unfinished_jobs
{"unfinished_jobs":
    [{"status": "Scheduled",
      "name": "ConfigBIOS:BIOS.Setup.1-1",
      "until_time": "TIME_NA",
      "start_time": "TIME_NOW",
      "message": "Task successfully scheduled.",
      "percent_complete": "0",
      "id": "JID_499377293428"}]}
Abandon BIOS Changes

Instead of committing, a pending change can be abandoned:

baremetal node passthru call --http-method DELETE <node> abandon_bios_config

The abandon command does not provide a response body.

Change Boot Mode

The boot mode of the iDRAC can be changed to:

  • BIOS - Also called legacy or traditional boot mode. The BIOS initializes the system’s processors, memory, bus controllers, and I/O devices. After initialization is complete, the BIOS passes control to operating system (OS) software. The OS loader uses basic services provided by the system BIOS to locate and load OS modules into system memory. After booting the system, the BIOS and embedded management controllers execute system management algorithms, which monitor and optimize the condition of the underlying hardware. BIOS configuration settings enable fine-tuning of the performance, power management, and reliability features of the system.

  • UEFI - The Unified Extensible Firmware Interface does not change the traditional purposes of the system BIOS. To a large extent, a UEFI-compliant BIOS performs the same initialization, boot, configuration, and management tasks as a traditional BIOS. However, UEFI does change the interfaces and data structures the BIOS uses to interact with I/O device firmware and operating system software. The primary intent of UEFI is to eliminate shortcomings in the traditional BIOS environment, enabling system firmware to continue scaling with industry trends.

The UEFI boot mode offers:

  • Improved partitioning scheme for boot media

  • Support for media larger than 2 TB

  • Redundant partition tables

  • Flexible handoff from BIOS to OS

  • Consolidated firmware user interface

  • Enhanced resource allocation for boot device firmware

The boot mode can be changed via the WSMAN vendor passthru interface as follows:

baremetal node passthru call <node> set_bios_config \
  --arg "BootMode=Uefi"

baremetal node passthru call <node> commit_bios_config \
  --arg "reboot=true"
baremetal node passthru call <node> set_bios_config \
  --arg "BootMode=Bios"

baremetal node passthru call <node> commit_bios_config \
  --arg "reboot=true"

idrac-redfish

Through the idrac-redfish vendor passthru interface these methods are available:

Method Name

HTTP Method

Description

eject_media

POST

Eject a virtual media device. If no device is provided then all attached devices will be ejected. Optional argument: boot_device - the boot device to eject, either, cd, dvd, usb or floppy.

Known Issues

Nodes go into maintenance mode

After some period of time, nodes managed by the idrac hardware type may go into maintenance mode in Ironic. This issue can be worked around by changing the Ironic power state poll interval to 70 seconds. See [conductor]sync_power_state_interval in /etc/ironic/ironic.conf.

PXE reset with “factory_reset” BIOS clean step

When using the UEFI boot mode` with non-default PXE interface, the factory reset can cause the PXE interface to be reset to default, which doesn’t allow the server to PXE boot for any further operations. This can cause a clean_failed state on the node or deploy_failed if you attempt to deploy a node after this step. For now, the only solution is for the operator to manually restore the PXE settings of the server for it to PXE boot again, properly. The problem is caused by the fact that with the UEFI boot mode, the idrac uses BIOS settings to manage PXE configuration. This is not the case with the BIOS boot mode where the PXE configuration is handled as a configuration job on the integrated NIC itself, independently of the BIOS settings.

WSMAN vendor passthru timeout

When iDRAC is not ready and executing WSMAN vendor passthru commands, they take more time as waiting for iDRAC to become ready again and then time out, for example:

baremetal node passthru call --http-method GET \
  aed58dca-1b25-409a-a32f-3a817d59e1e0 list_unfinished_jobs
Timed out waiting for a reply to message ID 547ce7995342418c99ef1ea4a0054572 (HTTP 500)

To avoid this need to increase timeout for messaging in /etc/ironic/ironic.conf and restart Ironic API service.

[DEFAULT]
rpc_response_timeout = 600

Timeout when powering off

Some servers might be slow when soft powering off and time out. The default retry count is 6, resulting in 30 seconds timeout (the default retry interval set by post_deploy_get_power_state_retry_interval is 5 seconds). To resolve this issue, increase the timeout to 90 seconds by setting the retry count to 18 as follows:

[agent]
post_deploy_get_power_state_retries = 18

Unable to mount remote share with iDRAC firmware before 4.40.40.00

When using iDRAC firmware 4.40.00.00 and consecutive versions before 4.40.40.00 with virtual media boot and new Virtual Console plug-in type eHTML5, there is an error: “Unable to mount remote share”. This is a known issue that is fixed in 4.40.40.00 iDRAC firmware release. If cannot upgrade, then adjust settings in iDRAC to use plug-in type HTML5. In iDRAC web UI go to Configuration -> Virtual Console and select Plug-in Type to HTML5.

During upgrade to 4.40.00.00 or newer iDRAC firmware eHTML5 is automatically selected if default plug-in type has been used and never changed. Systems that have plug-in type changed will keep selected plug-in type after iDRAC firmware upgrade.