Node cleaning¶
Overview¶
Ironic provides two modes for node cleaning: automated
and manual
.
Automated cleaning
is automatically performed before the first
workload has been assigned to a node and when hardware is recycled from
one workload to another.
Manual cleaning
must be invoked by the operator.
Automated cleaning¶
When hardware is recycled from one workload to another, ironic performs automated cleaning on the node to ensure it’s ready for another workload. This ensures the tenant will get a consistent bare metal node deployed every time.
Ironic implements automated cleaning by collecting a list of cleaning steps
to perform on a node from the Power, Deploy, Management, BIOS, and RAID
interfaces of the driver assigned to the node. These steps are then ordered by
priority and executed on the node when the node is moved to cleaning
state,
if automated cleaning is enabled.
With automated cleaning, nodes move to cleaning
state when moving from
active
-> available
state (when the hardware is recycled from one
workload to another). Nodes also traverse cleaning when going from
manageable
-> available
state (before the first workload is
assigned to the nodes). For a full understanding of all state transitions
into cleaning, please see Bare Metal State Machine.
Ironic added support for automated cleaning in the Kilo release.
Enabling automated cleaning¶
To enable automated cleaning, ensure that your ironic.conf is set as follows:
[conductor]
automated_clean=true
This will enable the default set of cleaning steps, based on your hardware and ironic hardware types used for nodes. This includes, by default, erasing all of the previous tenant’s data.
You may also need to configure a Cleaning Network.
Cleaning steps¶
Cleaning steps used for automated cleaning are ordered from higher to lower priority, where a larger integer is a higher priority. In case of a conflict between priorities across interfaces, the following resolution order is used: Power, Management, Deploy, BIOS, and RAID interfaces.
You can skip a cleaning step by setting the priority for that cleaning step to zero or ‘None’.
You can reorder the cleaning steps by modifying the integer priorities of the cleaning steps.
See How do I change the priority of a cleaning step? for more information.
Management Interface¶
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Clear the job queue. |
0 |
no |
|
|
Reset the iDRAC, Clear the job queue. |
0 |
no |
|
|
Reset the iDRAC. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Clear iDRAC job queue. |
0 |
no |
|
|
Clear all secure boot keys. |
0 |
no |
|
|
Export the configuration of the server. Exports the configuration of the server against which the step is run and stores it in specific format in indicated location. Uses Dell’s Server Configuration Profile (SCP) from sushy-oem-idrac library to get ALL configuration for cloning.
|
0 |
no |
|
|
Import and apply the configuration to the server. Gets pre-created configuration from storage by given location and imports that into given server. Uses Dell’s Server Configuration Profile (SCP).
|
0 |
no |
|
|
Import and export configuration in one go. Gets pre-created configuration from storage by given name and imports that into given server. After that exports the configuration of the server against which the step is run and stores it in specific format in indicated storage as configured by Ironic. |
0 |
no |
|
|
Reset iDRAC to known good state. An iDRAC is reset to a known good state by resetting it and clearing its job queue. |
0 |
no |
|
|
Reset the iDRAC. |
0 |
no |
|
|
Reset secure boot keys to manufacturing defaults. |
0 |
no |
|
|
Updates the firmware on the node. |
0 |
no |
|
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Clear the job queue. |
0 |
no |
|
|
Reset the iDRAC, Clear the job queue. |
0 |
no |
|
|
Reset the iDRAC. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Activates iLO Advanced license. |
0 |
no |
|
|
Clear all secure boot keys. Clears all the secure boot keys. This operation is supported only on HP Proliant Gen9 and above servers. |
0 |
no |
|
|
Resets the BIOS settings to default values. Resets BIOS to default settings. This operation is currently supported only on HP Proliant Gen9 and above servers. |
10 |
no |
|
|
Resets the iLO. |
0 |
no |
|
|
Resets the iLO password. |
30 |
no |
|
|
Reset secure boot keys to manufacturing defaults. Resets the secure boot keys to manufacturing defaults. This operation is supported only on HP Proliant Gen9 and above servers. |
20 |
no |
|
|
Updates the security parameters. |
0 |
no |
|
|
Updates the Auth Failure Logging Threshold security parameter. |
0 |
no |
|
|
Updates the firmware. |
0 |
no |
|
|
Clean step to update the firmware using Smart Update Manager (SUM) |
0 |
no |
|
|
Updates the Minimum Password Length security parameter. |
0 |
no |
|
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Activates iLO Advanced license. |
0 |
no |
|
|
Clears the certificates provided in the list of files to iLO. |
0 |
no |
|
|
Clear all secure boot keys. Clears all the secure boot keys. This operation is supported only on HP Proliant Gen9 and above servers. |
0 |
no |
|
|
Erase all the drives on the node. This method performs out-of-band sanitize disk erase on all the supported physical drives in the node. This erase cannot be performed on logical drives. |
0 |
no |
|
|
Erase the whole system securely. The One-button secure erase process resets iLO and deletes all licenses stored there, resets BIOS settings, and deletes all Active Health System (AHS) and warranty data stored on the system. It also erases supported non-volatile storage data and deletes any deployment setting profiles. |
0 |
no |
|
|
Resets the BIOS settings to default values. Resets BIOS to default settings. This operation is currently supported only on HP Proliant Gen9 and above servers. |
10 |
no |
|
|
Resets the iLO. |
0 |
no |
|
|
Resets the iLO password. |
30 |
no |
|
|
Reset secure boot keys to manufacturing defaults. Resets the secure boot keys to manufacturing defaults. This operation is supported only on HP Proliant Gen9 and above servers. |
20 |
no |
|
|
Updates the security parameters. |
0 |
no |
|
|
Updates the Auth Failure Logging Threshold security parameter. |
0 |
no |
|
|
Updates the firmware. |
0 |
no |
|
|
Clean step to update the firmware using Smart Update Manager (SUM) |
0 |
no |
|
|
Updates the Minimum Password Length security parameter. |
0 |
no |
|
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Restore BIOS config for a node. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Clear all secure boot keys. |
0 |
no |
|
|
Reset secure boot keys to manufacturing defaults. |
0 |
no |
|
|
Updates the firmware on the node. |
0 |
no |
|
Bios Interface¶
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Apply the BIOS settings to the node. |
0 |
no |
|
|
Reset the BIOS settings of the node to the factory default. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Apply the BIOS configuration to the node
|
0 |
no |
|
|
Reset the BIOS settings of the node to the factory default. This uses the Lifecycle Controller configuration to perform BIOS configuration reset. Leveraging the python-dracclient methods already available. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Applies the provided configuration on the node. |
0 |
no |
|
|
Reset the BIOS settings to factory configuration. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Applies BIOS configuration on the given node. This method takes the BIOS settings from the settings param and applies BIOS configuration on the given node. After the BIOS configuration is done, self.cache_bios_settings() may be called to sync the node’s BIOS-related information with the BIOS configuration applied on the node. It will also validate the given settings before applying any settings and manage failures when setting an invalid BIOS config. In the case of needing password to update the BIOS config, it will be taken from the driver_info properties. |
0 |
no |
|
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Apply the BIOS settings to the node. |
0 |
no |
|
|
Reset the BIOS settings of the node to the factory default. |
0 |
no |
Raid Interface¶
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create a RAID configuration on a bare metal using agent ramdisk. This method creates a RAID configuration on the given node. |
0 |
no |
|
|
Deletes RAID configuration on the given node. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create a RAID configuration. This method creates a RAID configuration on the given node. |
0 |
no |
|
|
Delete the RAID configuration. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create the RAID configuration. This method creates the RAID configuration on the given node. |
0 |
no |
|
|
Delete the RAID configuration. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create RAID configuration on the node. This method creates the RAID configuration as read from node.target_raid_config. This method by default will create all logical disks. |
0 |
no |
|
|
Delete RAID configuration on the node. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create the RAID configuration. This method creates the RAID configuration on the given node. |
0 |
no |
|
|
Delete the RAID configuration. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create a RAID configuration on a bare metal using agent ramdisk. This method creates a RAID configuration on the given node. |
0 |
no |
|
|
Delete the RAID configuration. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create the RAID configuration. This method creates the RAID configuration on the given node. |
0 |
no |
|
|
Delete the RAID configuration. |
0 |
no |
Name |
Details |
Priority |
Stoppable |
Arguments |
---|---|---|---|---|
|
Create RAID configuration on the node. This method creates the RAID configuration as read from node.target_raid_config. This method by default will create all logical disks. |
0 |
no |
|
|
Delete RAID configuration on the node. |
0 |
no |
Manual cleaning¶
Manual cleaning
is typically used to handle long running, manual, or
destructive tasks that an operator wishes to perform either before the first
workload has been assigned to a node or between workloads. When initiating a
manual clean, the operator specifies the cleaning steps to be performed.
Manual cleaning can only be performed when a node is in the manageable
state. Once the manual cleaning is finished, the node will be put in the
manageable
state again.
Ironic added support for manual cleaning in the 4.4 (Mitaka series) release.
Setup¶
In order for manual cleaning to work, you may need to configure a Cleaning Network.
Starting manual cleaning via API¶
Manual cleaning can only be performed when a node is in the manageable
state. The REST API request to initiate it is available in API version 1.15 and
higher:
PUT /v1/nodes/<node_ident>/states/provision
(Additional information is available here.)
This API will allow operators to put a node directly into cleaning
provision state from manageable
state via ‘target’: ‘clean’.
The PUT will also require the argument ‘clean_steps’ to be specified. This
is an ordered list of cleaning steps. A cleaning step is represented by a
dictionary (JSON), in the form:
{
"interface": "<interface>",
"step": "<name of cleaning step>",
"args": {"<arg1>": "<value1>", ..., "<argn>": <valuen>}
}
The ‘interface’ and ‘step’ keys are required for all steps. If a cleaning step method takes keyword arguments, the ‘args’ key may be specified. It is a dictionary of keyword variable arguments, with each keyword-argument entry being <name>: <value>.
If any step is missing a required keyword argument, manual cleaning will not be
performed and the node will be put in clean failed
provision state with an
appropriate error message.
If, during the cleaning process, a cleaning step determines that it has
incorrect keyword arguments, all earlier steps will be performed and then the
node will be put in clean failed
provision state with an appropriate error
message.
An example of the request body for this API:
{
"target":"clean",
"clean_steps": [{
"interface": "raid",
"step": "create_configuration",
"args": {"create_nonroot_volumes": false}
},
{
"interface": "deploy",
"step": "erase_devices"
}]
}
In the above example, the node’s RAID interface would configure hardware RAID without non-root volumes, and then all devices would be erased (in that order).
Starting manual cleaning via “openstack metal” CLI¶
Manual cleaning is available via the baremetal node clean
command, starting with Bare Metal API version 1.15.
The argument --clean-steps
must be specified. Its value is one of:
a JSON string
path to a JSON file whose contents are passed to the API
‘-’, to read from stdin. This allows piping in the clean steps. Using ‘-’ to signify stdin is common in Unix utilities.
The following examples assume that the Bare Metal API version was set via
the OS_BAREMETAL_API_VERSION
environment variable. (The alternative is to
add --os-baremetal-api-version 1.15
to the command.):
export OS_BAREMETAL_API_VERSION=1.15
Examples of doing this with a JSON string:
baremetal node clean <node> \
--clean-steps '[{"interface": "deploy", "step": "erase_devices_metadata"}]'
baremetal node clean <node> \
--clean-steps '[{"interface": "deploy", "step": "erase_devices"}]'
Or with a file:
baremetal node clean <node> \
--clean-steps my-clean-steps.txt
Or with stdin:
cat my-clean-steps.txt | baremetal node clean <node> \
--clean-steps -
Cleaning Network¶
If you are using the Neutron DHCP provider (the default) you will also need to ensure you have configured a cleaning network. This network will be used to boot the ramdisk for in-band cleaning. You can use the same network as your tenant network. For steps to set up the cleaning network, please see Configure the Bare Metal service for cleaning.
In-band vs out-of-band¶
Ironic uses two main methods to perform actions on a node: in-band and out-of-band. Ironic supports using both methods to clean a node.
In-band¶
In-band steps are performed by ironic making API calls to a ramdisk running on the node using a deploy interface. Currently, all the deploy interfaces support in-band cleaning. By default, ironic-python-agent ships with a minimal cleaning configuration, only erasing disks. However, you can add your own cleaning steps and/or override default cleaning steps with a custom Hardware Manager.
Out-of-band¶
Out-of-band are actions performed by your management controller, such as IPMI, iLO, or DRAC. Out-of-band steps will be performed by ironic using a power or management interface. Which steps are performed depends on the hardware type and hardware itself.
For Out-of-Band cleaning operations supported by iLO hardware types, refer to Node Cleaning Support.
FAQ¶
How are cleaning steps ordered?¶
For automated cleaning, cleaning steps are ordered by integer priority, where a larger integer is a higher priority. In case of a conflict between priorities across hardware interfaces, the following resolution order is used:
Power interface
Management interface
Deploy interface
BIOS interface
RAID interface
For manual cleaning, the cleaning steps should be specified in the desired order.
How do I skip a cleaning step?¶
For automated cleaning, cleaning steps with a priority of 0 or None are skipped.
How do I change the priority of a cleaning step?¶
For manual cleaning, specify the cleaning steps in the desired order.
For automated cleaning, it depends on whether the cleaning steps are out-of-band or in-band.
Most out-of-band cleaning steps have an explicit configuration option for priority.
Changing the priority of an in-band (ironic-python-agent) cleaning step
requires use of a custom HardwareManager. The only exception is
erase_devices
, which can have its priority set in ironic.conf. For instance,
to disable erase_devices, you’d set the following configuration option:
[deploy]
erase_devices_priority=0
To enable/disable the in-band disk erase using ilo
hardware type, use the
following configuration option:
[ilo]
clean_priority_erase_devices=0
The generic hardware manager first identifies whether a device is an NVMe
drive or an ATA drive so that it can attempt a platform-specific secure erase
method. In case of NVMe drives, it tries to perform a secure format operation
by using the nvme-cli
utility. This behavior can be controlled using
the following configuration option (by default it is set to True):
[deploy]
enable_nvme_secure_erase=True
In case of ATA drives, it tries to perform ATA disk erase by using the
hdparm
utility.
If neither method is supported, it performs software based disk erase using
the shred
utility. By default, the number of iterations performed
by shred
for software based disk erase is 1. To configure the number of
iterations, use the following configuration option:
[deploy]
erase_devices_iterations=1
Overriding step priority¶
[conductor]clean_step_priority_override
is a new configuration option
which allows specifying priority of each step using multiple configuration
values:
[conductor]
clean_step_priority_override=deploy.erase_devices_metadata:123
clean_step_priority_override=management.reset_bios_to_default:234
clean_step_priority_override=management.clean_priority_reset_ilo:345
This parameter can be specified as many times as required to define priorities for several cleaning steps - the values will be combined.
What cleaning step is running?¶
To check what cleaning step the node is performing or attempted to perform and
failed, run the following command; it will return the value in the node’s
driver_internal_info
field:
baremetal node show $node_ident -f value -c driver_internal_info
The clean_steps
field will contain a list of all remaining steps with their
priorities, and the first one listed is the step currently in progress or that
the node failed before going into clean failed
state.
Should I disable automated cleaning?¶
Automated cleaning is recommended for ironic deployments, however, there are
some tradeoffs to having it enabled. For instance, ironic cannot deploy a new
instance to a node that is currently cleaning, and cleaning can be a time
consuming process. To mitigate this, we suggest using NVMe drives with support
for NVMe Secure Erase (based on nvme-cli
format command) or ATA drives
with support for cryptographic ATA Security Erase, as typically the
erase_devices step in the deploy interface takes the longest time to complete
of all cleaning steps.
Why can’t I power on/off a node while it’s cleaning?¶
During cleaning, nodes may be performing actions that shouldn’t be interrupted, such as BIOS or Firmware updates. As a result, operators are forbidden from changing power state via the ironic API while a node is cleaning.
Troubleshooting¶
If cleaning fails on a node, the node will be put into clean failed
state.
If the failure happens while running a clean step, the node is also placed in
maintenance mode to prevent ironic from taking actions on the node. The
operator should validate that no permanent damage has been done to the
node and no processes are still running on it before removing the maintenance
mode.
Note
Older versions of ironic may put the node to maintenance even when no clean step has been running.
Nodes in clean failed
will not be powered off, as the node might be in a
state such that powering it off could damage the node or remove useful
information about the nature of the cleaning failure.
A clean failed
node can be moved to manageable
state, where it cannot
be scheduled by nova and you can safely attempt to fix the node. To move a node
from clean failed
to manageable
:
baremetal node manage $node_ident
You can now take actions on the node, such as replacing a bad disk drive.
Strategies for determining why a cleaning step failed include checking the ironic conductor logs, viewing logs on the still-running ironic-python-agent (if an in-band step failed), or performing general hardware troubleshooting on the node.
When the node is repaired, you can move the node back to available
state,
to allow it to be scheduled by nova.
# First, move it out of maintenance mode
baremetal node maintenance unset $node_ident
# Now, make the node available for scheduling by nova
baremetal node provide $node_ident
The node will begin automated cleaning from the start, and move to
available