Configuration¶
To enable the ironic-prometheus-exporter to collect the sensor data from Ironic,
it’s necessary to enable some configuration parameters in the ironic.conf
.
Below you can see an example of the required configuration, the table
Configuration options for the ironic-prometheus-exporter in Ironic shows all the available configuration options.
Example of configuration
[conductor]
send_sensor_data = true
send_sensor_data_interval = 300
[oslo_messaging_notifications]
driver = prometheus_exporter
transport_url = fake://
location = /opt/stack/node_metrics
Section |
Setting |
Value |
Description |
Required |
---|---|---|---|---|
conductor |
send_sensor_data |
true |
Enable sending sensor data message via the notification bus. |
|
conductor |
send_sensor_data_interval |
600 (default) |
Seconds between conductor sending sensor data message via the notification bus. |
|
conductor |
send_sensor_data_for_undeployed_nodes |
false (default) |
When set to true, the conductor will collect sensor information from
all nodes when sensor data collection is enabled via the
|
No |
oslo_messaging_notifications |
driver |
prometheus_exporter |
The Drivers(s) to handle sending notifications. |
|
oslo_messaging_notifications |
transport_url |
fake:// |
A URL representing the messaging driver to use for notifications. If not set, we fall back to the same configuration used for RPC. |
|
oslo_messaging_notifications |
location |
<dir_path> |
Directory where the files will be written. |
|
Note
After doing the modifications in the ironic.conf
don’t forget to re-start
the ironic-conductor service